Sanaei 6aefb14569 fix(xray): keep the config snapshot true after a runtime inbound change
The process snapshot is what a reconcile diffs the desired config against,
so it has to describe what the core is running. The local runtime added and
removed inbounds over gRPC without telling it:

- An inbound added at runtime was missing from the snapshot. The next
  reconcile saw it as new, hit "existing tag", and replaced the handler: the
  listener closed and every client on it was cut. On a WireGuard inbound all
  peers lost their tunnel for about 15 s, once, at the first device or
  client change after the inbound was created.
- An inbound removed at runtime stayed in the snapshot. Enabling it again
  through a path that only asks for a reconcile diffed as "no change", and
  the core never got it back.

The local runtime now reports both to the process, which swaps in an edited
copy of the snapshot. The wiring moved into XrayService.LocalRuntimeDeps so
the tests run the panel's own bridge against an in-process core and compare
handler identity before and after the reconcile.

User-level drift is left to the reconcile, which already settles it without
touching a session: a known WireGuard peer is updated in place, any other
user is re-added by credential, and a missing one is skipped.